Working towards a cleaner futureSirius SATBuilt-in User ModulesR/1 – RP/1 – RS – RSP – R2ZInstallation and Operating ManualAugust 2010heating speciali
10912.808.1 - ITINSTALLATION AND OPERATING MANUALTABLE: HEAT DEMAND – FLOW OF WATER IN HEATING CIRCUIT
11912.808.1 - ITINSTALLATION AND OPERATING MANUAL0607_0201 / CR_0029Figure 2: Casing/templateCASING/TEMPLATE MODEL WIDTH SIRIUS SAT MODELSSINGLE-ZONE
12912.808.1 - ITINSTALLATION AND OPERATING MANUAL0902_0804 / CR_0017Figure 3 A: Connectors and sizes of SIRIUS SAT R/1 – RP/1 – RS – RSPAfter compl
13912.808.1 - ITINSTALLATION AND OPERATING MANUALModels R/1These models are tted with a balancing valve (gure 5). This device is used to balance th
14912.808.1 - ITINSTALLATION AND OPERATING MANUALFigure 5: Balancing valve (models without Pump)0807_3103 / CR_01850807_3104 / D_2151
15912.808.1 - ITINSTALLATION AND OPERATING MANUALThese models are tted with a circulation pump.This silent-running high-head pump is suitable for us
16912.808.1 - ITINSTALLATION AND OPERATING MANUALThe models with domestic hot water production are tted with an instantaneous plate exchanger in sta
17912.808.1 - ITINSTALLATION AND OPERATING MANUALFigure 8 A: Domestic water meters (models R/1)1st meter (models R/1 – RP/1 – R2Z)Domestic water mete
18912.808.1 - ITINSTALLATION AND OPERATING MANUAL0707_2603 / CR_0032Figure 8 D: Domestic water meter (Models RS – RSP – RS2Z)1st meter (models RS –
19912.808.1 - ITINSTALLATION AND OPERATING MANUALThe appliance is sold complete with electrical connections and power cable.This machine is only elec
2912.808.1 - ITINSTALLATION AND OPERATING MANUALTO THE OWNER OF THIS POTTERTON COMMERCIAL APPLIANCEWe are condent your new POTTERTON COMMERCIAL appl
20912.808.1 - ITINSTALLATION AND OPERATING MANUAL11. WIRING DIAGRAMS11.1 MODELS R/1 E RP/1T.A.0902_0808 / CR_0128MAINS POWER INPUT230V-50HzFUSEPOWER
21912.808.1 - ITINSTALLATION AND OPERATING MANUAL11.2 MODELS RS0902_0809 / CR_008MAINS POWER INPUT230V-50HzON/OFF BUTTONDOMESTIC WATER PRIORITY SENSO
22912.808.1 - ITINSTALLATION AND OPERATING MANUAL11.3 MODELS RSP0902_0810 / CR_009MAINS POWER INPUT230V-50HzON/OFF BUTTONDOMESTIC WATER PRIORITY SENS
23912.808.1 - ITINSTALLATION AND OPERATING MANUAL11.4 MODELS R2Z0902_0811 / CR_007MAINS POWER INPUT230V-50HzON/OFF BUTTONMIXING VALVE SERVOMOTOREXTER
24912.808.1 - ITINSTALLATION AND OPERATING MANUAL11.5 MODELS RS2Z0902_0812 / CR_0010MAINS POWER INPUT230V-50HzON/OFF BUTTONDOMESTIC WATER PRIORITY SE
25912.808.1 - ITINSTALLATION AND OPERATING MANUALAccess the electrical components as described in section 10.1.Remove the jumper on terminals (1) and
26912.808.1 - ITINSTALLATION AND OPERATING MANUALWhen connecting the user module to a system operating at low temperature, install an off-the-shelf m
27912.808.1 - ITINSTALLATION AND OPERATING MANUAL(accessory available on request for models RS, RSP, R2Z, RS2Z)The appliance is tted for connection
28912.808.1 - ITINSTALLATION AND OPERATING MANUAL(accessory available on request: models RS – RSP – R2Z – RS2Z)The LUNASAT module can be remote contr
29912.808.1 - ITINSTALLATION AND OPERATING MANUAL0902_0819 / CR_0014Figure 13 B: Domestic hot water potentiometerSELECTORS 1 – 2 – 3 : USER MODULE CO
3912.808.1 - ITINSTALLATION AND OPERATING MANUAL1. Description 42. Instructions prior to installation 4CONTENTS3. Centralised system requirements
30912.808.1 - ITINSTALLATION AND OPERATING MANUALSWITCHES 4 – 5 : CLIMATE CURVE SELECTION (only for models RSP-R2Z-RS2Z))Climate curve selection tabl
31912.808.1 - ITINSTALLATION AND OPERATING MANUALSWITCH 6: EXTERNAL PROBE ENABLE (only for models RSP-R2Z-RS2Z))External probe enable tableEXTERNAL P
32912.808.1 - ITINSTALLATION AND OPERATING MANUALThe modules are supplied standard with a SIEMENS MEGATRON electronic heat meter.This device measures
33912.808.1 - ITINSTALLATION AND OPERATING MANUALThis system allows all the consumption data of the building to be handled from a single station, thu
34912.808.1 - ITINSTALLATION AND OPERATING MANUALFigure 15 A: Automatic measurement system via radio0902_0905 / CR_0027RADIO TRANSMISSION 868 MHzPHON
35912.808.1 - ITINSTALLATION AND OPERATING MANUALFigure 15 B: Reading options0902_0904 / CR_00331) LOCAL TRANSMISSION VIA “SERIAL”2) LOCAL TRANSMI
36912.808.1 - ITINSTALLATION AND OPERATING MANUALStart-up of the radio system comprises several steps:r 4FUUIF855BFSJBMTUPUIFTUBSUVQNPEF
37912.808.1 - ITINSTALLATION AND OPERATING MANUALBefore starting the user module, open the on/off valves on the hydraulic connectors and check the sy
38912.808.1 - ITINSTALLATION AND OPERATING MANUAL21. OPERATING PROCEDURETo start the appliance correctly, proceed as follows:r 1PXFSUIFNPEVMFr $
39912.808.1 - ITINSTALLATION AND OPERATING MANUAL5IFNPEFMTXJUIFMFDUSPOJDCPBSEEJTQMBZUIFPQFSBUJOHTUBUVTBOEBOZTZTUFNCMPDLTWJBUIFCPBSE-&
4912.808.1 - ITINSTALLATION AND OPERATING MANUALThe SIRIUS SAT user modules make it possible to independently manage heating requirements in centrali
40912.808.1 - ITINSTALLATION AND OPERATING MANUALFigure 16: Electronic board signals0902_0906 / CR_0024Safety thermostat trippingRed indicator LEDGre
41912.808.1 - ITINSTALLATION AND OPERATING MANUALFor regular and cost-effective operation of the user modules, they must be periodically checked and
42912.808.1 - ITINSTALLATION AND OPERATING MANUALThese appliances are tted with a heating water lter on the water inlet line coming from the centra
43912.808.1 - ITINSTALLATION AND OPERATING MANUALThe module is tted with a cold water lter on the hydraulic assembly.To clean, proceed as follows:r
44912.808.1 - ITINSTALLATION AND OPERATING MANUAL26. FUNCTIONAL CIRCUIT DIAGRAM26.1 MODEL R/10902_0907 / CR_0138KeyY1 ON-OFF valveC1 Meter PLANT HEAT
45912.808.1 - ITINSTALLATION AND OPERATING MANUAL0902_1102 / CR_013926.2 MODEL RP/1PLANT HEATINGDELIVERYHEATING INLET FROMCENTRAL PLANTHEATING RETURN
46912.808.1 - ITINSTALLATION AND OPERATING MANUAL26.3 MODEL RS0902_0909 / CR_0004KeyY1 ON-OFF valveY2 Modulating valveY3 DHW/heating three-way val
47912.808.1 - ITINSTALLATION AND OPERATING MANUAL0902_0910 / CR_000526.4 MODEL RSPKeyY1 ON-OFF valveY2 Mixing valveY3 DHW/heating three-way valveP1
48912.808.1 - ITINSTALLATION AND OPERATING MANUAL0902_0911 / CR_000326.5 MODEL R2ZKeyY1 ON-OFF valve Y2 Mixing valve l.v. Y3 ON-OFF valveB4 Heating
49912.808.1 - ITINSTALLATION AND OPERATING MANUAL0902_0912 / CR_000626.6 MODEL RS2ZKeyY1 ON-OFF valveY2 Mixing valveY3 DHW/heating three-way valveY4
5912.808.1 - ITINSTALLATION AND OPERATING MANUALSome general indications concerning the installation of the centralised heating system are shown belo
50912.808.1 - ITINSTALLATION AND OPERATING MANUALThis product has been built with materials that do not pollute the environment. At the end of its li
51912.808.1 - ITINSTALLATION AND OPERATING MANUAL
Baxi Commercial DivisionWood Lane, Erdington, Birmingham B24 9QP Email: [email protected]:0845 070 1056Technical
6912.808.1 - ITINSTALLATION AND OPERATING MANUAL0903_2001 / CR_0034Figure 1A: Diagram of plant: centralised domestic hot water productionCENTRAL HEAT
7912.808.1 - ITINSTALLATION AND OPERATING MANUAL0903_2002 / CR_0012Figure 1B: Diagram of plant: local domestic hot water productionCENTRAL HEATINGDOM
8912.808.1 - ITINSTALLATION AND OPERATING MANUAL0903_2003p / CR_0013Figure 1C: Floor layoutThe indicative diagram in gure 1c only illustrates the fe
9912.808.1 - ITINSTALLATION AND OPERATING MANUAL- Campo temperatura acqua impianto centralizzato: 60 - 75 °C- Water temperature range in centralise